IPC-A-610C
Multiserve Inspection Standards
Incoming Material Inspection Standard :
IQC Sampling Plan :
MIL-STD-105E
AQL=0.65%
Single Sampling
Typical Class II Verification Level
The PCB Incoming Material Inspection to check :
Supplier Outgoing Inspection Report
Supplier Impedance Test Report
Inspection Items: PCB Version, Date Cord, Dimensions, Hole Size, Pad Size, Solder Mask
In Process Quality Control :
First-Piece Inspection Standard
Process Inspection Standard
For Patrol Inspection:
Functional Monitor (FOQM): MIL-STD-1235C (CSP-1)
Visual Monitor (VOQM): MIL-STD-1235C (CSP-2)
Final Quality Control :
Process Inspection Standard
FQC Sampling Plan :
Inspection Items : Surface, Function, Packing
MIL-STD-105E
AQL=0.65%
Single Sampling
Typical Class II Verification Level
Outgoing Quality Control :
Process Inspection Standard
OQC Sampling Plan
Inspection Items : Surface, Function, Packing
Sampling :5~1000pcs
Increased By 1000pcs:5pcs addition
C=0



On Receipt Of R.M.A. Product, The Following "Defectives Management Procedure" :
Sales Department to complete "Return Worksheet" to be forwarded with the faulty R.M.A. products to the Manufacture Department.
Production Control Department to open R.M.A. Worksheet
QA Department will determine fault and indicate problem to be fixed.
Service And Maintenance Department to fix faulty goods and record problem for reference.
QA Department to approve the fixed item before its return to customer.